Campbell Hausfeld Air Compressor Introduction, Safety Guidelines, Setting Up Your Unit, and Maintenance Tips and Air Compressor Troubleshooting

We’ve captured some of the highlights of the operator’s manual for the CE line of air compressors by Campbell Hausfeld. We hope this is a helpful resource for you if you have any questions about such topics as related to your unit.


The Campbell Hausfeld CE Series air compressors are two stage, oil lubricated reciprocating compressors. Among the compressors we carry are the CE6000, the CE7050, the CE7000. (The CE7050 and CE7000 are also available as “full package” options or automotive seies. See more below.)  There are two configurations:

Shop Air Series (basic) and Automotive Series Compressors (fully packaged).

Shop Air Models Include:
  • Compressor pump
  • ASME air receiver with safety valve
  • Electric Motor or gas engine
  • Starter
  • Pressure switch
Automotive Series Models Include:
  • All of the features of the Shop Air models
  • Air cooled aftercooler
  • Digitial hour meter
  • Automatic tank drain
  • Low oil guard
  • Vibration isolation pads
  • Shut off valve
Quick Reference
Recommended Oil (2 options)
-Single viscosity SAE 30 IS100 nondetergent compressor oil.
-10W30 synthetic oil such as Mobil 1

Oil Capacity
CE7000 Series: 2 Quarts
CE8000 Series: 4 Quarts

SAFETY GUIDELINES

DANGER
sign indicates an imminently hazardous situation which, if not avoided, WILL result in death or serious injury.

WARNING
sign indictates a potentially hazardous situation which, if not avoided, COULD result in death or serious injury.

CAUTION
sign indictates a potentially hazardous situation which, if not avoided, MAY result in death or serious injury.

NOTICE
sign indictates important information, that, if not followed, may cause damage to equipment.

IMPORTANT SAFETY INFORMATION

Since the air compressor and other components (material pump, spray guns, filters, lubricators, hoses, etc) used make up a high pressure pumping system, the following safety precautions must be observed at all times.

GENERAL SAFETY

  • Read all manuals included with this product carefully. Be thoroughly familiar with the controls and the proper use of the equipment.
  • Follow all local electrical and safety codes as well as the United States National Electric Codes (NEC) and Occupational Safety and Health Act (OSHA).
  • Only persons well acquainted with these rules of safe operation should be allowed to use the compressor.
  • Keep visitors away and NEVER allow children in the work area.
  • Wear safety glasses and use hearing protection when operating the unit.
  • Do not stand on or use the unit as a handhold.
  • Before each use, inspect compressed air system and electrical components for signs of damage, deterioration, weakness, or leakage. Repair or replace defective items before using.
  • Check all fasteners at frequent intervals for proper tightness.
  • Keep fingers away from a running compressor; fast moving and hot parts will cause injury and / or burns.
  • If the equipment should start to vibrate abnormally, STOP the engine /motor and check immediately for the cause. Vibration is generally an indication of trouble.
  • To reduce fire hazard, keep engine /motor exterior free of oil, solvent, or excessive grease.
NOTICE: Drain liquid from tank daily.
Tanks rust from moisture build-up, which weakens the tank. Make sure to drain tank regularly and inspect periodically for unsafe conditions such as rust formation and corrosion. Fast moving air will stir up dust and debris which may be harmful. Release air slowly when draining moisture or depressurizing the compressor system.

SPRAYING PRECAUTIONS
  • Do not smoke when spraying paint, insecticides, or other flammable substances.
  • Use a face mask / respirator when spraying and spray in a well-ventilated area to prevent health and fire hazards
  • Do not direct paint or other sprayed material at the compressor.
  • Locate compressor as far away from the spraying area as possible to minimize overspray accumulation on the compressor.
  • When spraying or cleaning with solvents or toxic chemicals, follow the instructions provided by the chemical manufacturer.
UNPACKING
After unpacking the unit, inspect carefully for any damage that may have occurred during transit. Check for loose, missing, or damaged parts. Check to be sure all supplied accessories are enclosed with the unit.

REQUIRED ITEMS (not included)

  • oil
  • vibration isolator pads (Shop Air Series only)
INSTALLATION
Picking the location
Install and operate unit at least 18″ from any obstructions in a clean and well-ventilated area. The air temperature should not exceed 100 degrees farenheit. This will ensure an unobstructed flow of air to cool the compressor and allow adequate space for maintenance.

CAUTION:
Do not locate the compressor air inlet near steam, paint spray, sandblast areas, or any other source of contamination.


Note: If compressor operates in a hot, moist environment, supply compressor pump with clean, dry outside air. Supply air should be piped in from external sources.


Tank Mounting

The tank should be bolted into a flat, even concreate floor or on a separate concrete foundation. Vibration isolators should be used between the tank leg and the floor. Model MP349500AJ isolator pads are recommended for horizontal units. Model MP345700AJ isolator pads are recommended for vertical units. Isolator pads are included with fully packaged models. If you are in need of isolator pads, please call Clark at 603-234-2612.

When using isolator pads do not draw bolts tight. Allow the pads to absorb vibrations. When isolators are used, a flexible hose or coupling should be installed between the tank and service piping.

WARNING:
Failure to properly install the tank can lead to cracks at the welded joints and possible bursting.


PIPING

Any tube, pipe, or hose connected to the unit must be able to withstand the temperature generated and retain the pressure. All pressurized components of the air system must have a pressure rating of 200 psi or higher. Incorrect selection and installation of any tube, pipe, or hose could result in bursting and injury. Connect piping system to tank using the same fitting as the discharge port.

INSTALLING A SHUT-OFF VALVE

A shut-off valve should be installed on the discharge port of the tank to control the air flow out of the tank. the valve should be located between the tank and the piping system.

WARNING:
Never install a shut-off valve between the compressor pump and the tank. Personal injury and /or equipment damage may occur. Never use reducers in discharge piping.


When creating a permanently installed system to distribute compressed air, find the total length of the system and select pipe size from the chart. Bury underground lines below the frost line and avoid pockets where condensation can gather and freeze.

Apply air pressure to the piping installation and make sure all joints are free from leaks BEFORE underground lines are covered. Before putting the compressor into service, find and repair all leaks in the piping, fittings, and connections.

WIRING

Wiring must be installed in accordance with National Electrical code and local codes and standards that have been set up covering electrical apparatus and wiring. These should be consulted and local ordinances observed. Be certain that adequate wire sizes are used, and that:

1. Service is of adequate ampere rating.
2. The supply line has the same electrical characteristics (voltage, cycles and phase) as the motor. Refer to motor name plate for electrical ratings and specifications.
3. The line wire is the proper size and that no other equipment is operated from the same line. The chart gives minimum recommended wire sizes for compressor installations.

GROUNDING

This product MUST be grounded. Grounding reduces the risk of electrical shock by providing an escape wire for the electric current if short circuit occurs. this product must be installed and operated with a power cord or cable that has a grounding wire.

BREAKERS AND FUSES

The entire electrical system should be checked by a certified electrician. Time delay breakers and fuses may indicate a direct short to ground, high current draw, improper wiring, incorrect fuse or breaker size and/or type. This needs to be evaluated by a certified electrician.

COMPRESSOR LUBRICATION

Add oil as required. The oil and oil filter should be changed every 3 months or after every 500 hours of operation; whichever comes first. If the compressor is operated under humid conditions for short periods of time, the humidity will condense in the crankcase and cause the oil to look creamy. Oil contaminated by condensed water will not provide adequate lubrication and must be changed immediately. Using contaminated oil will damage bearings, pistons, cylinders and rings and is not covered under warranty. To avoid water condensation in the oil, periodically run the compressor with tank pressure near 150 psi for two stage compressors or 120 psi for single stage compressors by opening the drain cock or an air valve connected to the tank or hose. run the pump for an hour at a time at least once a week or more often if the condensation reoccurs.

IMPORTANT:
Change oil after first 50 hrs of operation


AIR FILTER

Never run the compressor pump without an intake air filter or with a clogged intake air filter. The air filter element should be checked monthly.

Operating compressor with a dirty air filter can cause high oil consumption and increase oil contamination in the discharge air. If the air filter is dirty, it must be replaced.

INTERCOOLER

Check the intercooler weekly to be sure all fittings are secure and tight. Clean all dirt, dust and other accumulations from the intercooler fins.

COMPONENTS

Turn off all power and clean the cylinder head, motor, fan blades, air lines, intercooler, and tank on a monthly basis.

BELTS

Check belt tension every three months. Adjust belt tension to allow 3/8″ to 1/2″ deflection with normal thumb pressure. Also, align belts using a straight edge against the face of the flywheel and touching the rim on both sides of the face. The belts should be parallel to this straight edge. Dimension A should be the same as B and C to ensure proper alignment of the belts. Slots in the bedplate allow you to slide the motor back and forth to adjust belt tension.

We hope these highlights from the operator’s manual have been helpful to you. We aim to post a Troubleshooting Guide as well, to give customers easy access to finding what they need in case you run into any mechanical issues – it will be set up in a Symptom – Cause- Solution type of format, for easy reading. And finally–please let us know if this was helpful for you by leaving comments below! If not…what would you like to see on this blog?


PART II YOUR JOURNEY WITH YOUR AIR COMPRESSOR - TROUBLESHOOTING GUIDE

As promised we are posting our follow up to our Campbell Hausfeld Air Compressor User’s Manual. The follow is a TROUBLE SHOOTING GUIDE FOR NEW CAMPBELL HAUSFELD INSTALLATIONS. We hope it is of use to those of you who have purchased a Campbell Hausfeld air compressor.
——————————————————————————-
SYMPTOM: Unit fails to start- Motor makes no noise

CAUSE
Insufficient power to compressor
SOLUTION
Source electric to the compressor is either the incorrect voltage, insufficient wire size to carry the load, the fuse box or breaker box is not sufficient to carry the load, requirements to the compressor.
CAUSE
Wrong voltage supplied to unit
SOLUTION
Make sure voltage is correct with the motor wiring
CAUSE
Loose electrical connections
SOLUTION
The entire electrical system should be checked by a certified electrician. The incoming wires and the compressor electrical connections should be checked. Loose connections will cause malfunctions.
CAUSE
Wrong size wiring
SOLUTION
Check that wire size is rated for the current of the compressor. State and local codes vary widely and need to be checked before installation.
CAUSE
Blown fuse and/or tripped
SOLUTION
The breaker and fuses required for this unit must be time delay. A tripped breaker or blown fuse may result from a direct short to ground, high current draw, improper wiring, incorrect fuse or breaker size and/or type. This needs to be evaluated by a service center or certified electrician.
CAUSE
Starter overload tripped
SOLUTION
Check and reset if necessary. If the overload trips after the initial reset, refer to the section of the manaul that covers this issue.
CAUSE
Low oil level
SOLUTION
Units equipped with a low oil guard must have proper oil to operate. If oil level is low, add more oil. Unplug the compressor to reset the relay for the low oil switch.
——————————————————————————-
SYMPTOM: Unit fails to start – Motor hums

CAUSE
SOLUTION
Any wiring other than what is stated in the manual could cause a malfunction
CAUSE
Wrong voltage
SOLUTION
Make sure voltage is corrct with the motor wiring
CAUSE
Loose electrical connections
SOLUTION
The entire electrical system should be checked by a certified electrician. The incoming wires and the compressor electrical connections should be checked. Loose connections will cause malfunctions.
——————————————————————————-
SYMPTOM: Motor reset button trips or reset trips on starter

CAUSE
Unit wired incorrectly
SOLUTION
Check voltage, wire size, etc. This problem needs to be evaluated and corrected.
CAUSE
Wrong voltage
SOLUTION
Make sure voltage is incorrect with the motor wiring.
CAUSE
Wrong size wiring
SOLUTION
Check to make sure wire size is rated for the current of the compressor.
——————————————————————————-
SYMPTOM: Unit starts but does not get to full speed

CAUSE
Insufficient power to compressor
SOLUTION
Source electric to the compressor is either the incorrect voltage, insufficient wire size to carry the load, the fuse box or breaker box is not sufficient to carry the load requirements to the compressor.
CAUSE
Loose Electrical Connections
SOLUTION
The entire electrical system should be checked by a certified electrician. The incoming wires and the compressor electrical connections should be checked. Loose connections will cause malfunctions.
——————————————————————————-
SYMPTOM: Unit does not make any or very little air

CAUSE
Drain valve open
SOLUTION
Make sure the drain valve at the bottom of the tank is closed.
CAUSE
Air Leak
SOLUTION
Check the entire system for leaks, including the compressor unit and any piping attached to the compressor.
CAUSE
Restricted or blocked intake
SOLUTION
Make sure that the air intake of the compressor is not blocked in any way.
——————————————————————————-
SYMPTOM: Unit runs very noisy

CAUSE
Damage to the compressor
SOLUTION
Check to make sure the compressor has not been damaged in the shipping or installation. Make sure the belt guard was not damaged. Belt guard should not be making contact with flywheel or pulley.
CAUSE
Loose fasteners
SOLUTION
Check all bolts and nuts to assure they did not loosen during shipping.
CAUSE
Loose flywheel or pulley
SOLUTION
Check to assure pulley and flywheel are correctly tightened.
CAUSE
Improper installation
SOLUTION
If unit is left on skid, it may cause excessive vibration. Remove unit from skid and mount loosely to floor with vibration pads and anchor bolts. Do not tighten bolts tight. Leave nut loose approximately 1/8″ from compressor foot.
——————————————————————————-
SYMPTOM: Oil in discharge air or out crankcase breather

CAUSE
Break in period
SOLUTION
Some oil in the exhaust air is normal during the break-in period and during heavy usage after the break-in period. Oil discharge should reduce as hours are accumulated on the unit.
CAUSE
Wrong type of oil
SOLUTION
Do not use SAE-30 automotive type oil. Using the wrong oil can cause problems with the pump and will void the warrenty. Only use the oils that the operating manual recommends.
CAUSE
Improper environment
SOLUTION
Unit should not be installed in a poorly ventilated area or exposed to extreme cold or hot conditions. Normal operating range should be between 32 degrees F and 100 degrees F.